{"id":7298,"date":"2026-06-16T15:20:25","date_gmt":"2026-06-16T15:20:25","guid":{"rendered":"https:\/\/products.barox.ch\/produkte\/unkategorisiert\/ry-lpite-442xgme-4\/"},"modified":"2026-06-16T15:20:34","modified_gmt":"2026-06-16T15:20:34","slug":"ry-lpite-442xgme","status":"publish","type":"product","link":"https:\/\/products.barox.ch\/fr\/produits\/switches\/ry-lpite-442xgme\/","title":{"rendered":"RY-LPITE-442XGME"},"content":{"rendered":"<p>Ce Switch robuste et de haute qualit\u00e9 est con\u00e7u pour une utilisation dans des structures de r\u00e9seau en anneau Ethernet 10, 100 et 1000MBit\/s selon IEEE802.x. Les huit ports en cuivre disposent d&rsquo;une alimentation par Ethernet avec PoE, PoE+ et PoE++. Ces appareils ont \u00e9t\u00e9 sp\u00e9cialement d\u00e9velopp\u00e9s pour les r\u00e9seaux vid\u00e9o. Le Switch permet la construction d&rsquo;un ou plusieurs anneaux \u00e0 tol\u00e9rance de pannes via deux ou plusieurs connexions. En cas d&rsquo;interruption, l&rsquo;anneau se ferme automatiquement en moins de 50ms. Cela am\u00e9liore la disponibilit\u00e9 du syst\u00e8me.Deux emplacements SFP pour 1\/10Gbit\/s sont disponibles pour le backbone, qui peuvent \u00eatre \u00e9quip\u00e9 en multimode ou monomode. Les Switches peuvent \u00e9galement \u00eatre utilis\u00e9s comme appareils autonomes, pour des connexions point \u00e0 point ou comme modules de connexion. Les possibilit\u00e9s \u00e9tendues du logiciel de gestion permettent \u00e9galement l&rsquo;utilisation du Switch dans des syst\u00e8mes \u00e0 haute fonctionalit\u00e9. L&rsquo;installation est tr\u00e8s facile gr\u00e2ce au dispositif de montage pour rails de montage. Les connexions \u00e9lectriques et optiques sont assur\u00e9es par des blocs d&rsquo;alimentation en norme (RJ45 ou LC).<\/p>\n<h2>Produktinformationen<\/h2>\n<h4>Kurzbeschreibung<\/h4>\n<p>Switch Industriel L2\/L3 avec management, fonctionnalit\u00e9s de s\u00e9curit\u00e9 renforc\u00e9es et ports SFP PoE ++ 10 Gbit<\/p>\n<h4>Besonderheit f\u00fcr Videonetzwerke<\/h4>\n<p><strong><strong>Surveillance active de la cam\u00e9ra<\/strong><\/strong><br \/>Les cam\u00e9ras aliment\u00e9es par le Switch via PoE sont surveill\u00e9es en permanence. En cas de panne de la cam\u00e9ra, le Switch red\u00e9marre automatiquement la cam\u00e9ra. En cas d&rsquo;\u00e9chec, le Switch envoie un message d&rsquo;alarme via SNMP.<\/p>\n<p><strong><strong>Surveillance active de l&rsquo;alimentation PoE<\/strong><\/strong><br \/>Si, par exemple, une cam\u00e9ra d\u00e9fectueuse consomme trop d&rsquo;alimentation de la part du Switch, ce dernier \u00e9met une alerte via SNMP.<\/p>\n<p><strong><strong>Gestion active de la performance des PoE<\/strong><\/strong><br \/>Lorsque le Switch est d\u00e9marr\u00e9, les ports PoE individuels peuvent \u00eatre d\u00e9marr\u00e9s avec un d\u00e9calage temporaire pour \u00e9viter une surcharge de l&rsquo;alimentation PoE.<\/p>\n<p><strong><strong>Fonctionnalit\u00e9s suppl\u00e9mentaires compatibles avec la vid\u00e9o<\/strong><\/strong><br \/>Performances de backplane tr\u00e8s \u00e9lev\u00e9e pour une transmission vid\u00e9o fluide m\u00eame \u00e0 pleine charge des ports. Les frames Jumbo jusqu&rsquo;\u00e0 9600Bytes sont \u00e9galement support\u00e9es \u00e0 100MBit\/s. S\u00e9curit\u00e9 du port par restriction d&rsquo;adresses MAC.<\/p>\n<h4>Systemhinweise<\/h4>\n<p>Le switch prend en charge PTP, protocole de temps de pr\u00e9cision selon IEEE1588 v2 et IEC 61588. Cette fonction est utilis\u00e9e, entre autres, dans l&rsquo;automatisation industrielle, dans les applications audio-vid\u00e9o professionnelles pour le pontage audio-vid\u00e9o et dans les t\u00e9l\u00e9communications.<br \/>Le switch prend \u00e9galement en charge les protocoles de routage dynamique OSPFv2\/v3 et RIPv1\/v2.<br \/>S-VLAN peut \u00eatre utilis\u00e9 pour la structure VLAN avec les fournisseurs de services.<\/p>\n<h2>Technische Daten<\/h2>\n<h4>Distanzangabe<\/h4>\n<p><span style=\"font-size: 16px;\"><\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Montage sur rail DIN|Ports cuivre : 8 x10|Ports Fibre : 2 x SFP\/SFP+ 1G\/10G|Avec management, fonctions L3|Non Stop PoE|OSPFv2\/v3 und RIPv1\/v2|IEEE 1588 V2, PTP|Sans ventilateur|Alimentation 48-57VDC, redondont<\/p>\n","protected":false},"featured_media":7004,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[129],"product_tag":[],"class_list":["post-7298","product","type-product","status-publish","has-post-thumbnail","product_cat-switches","pa_abmessungen-170x70x130mm-hxbxl","pa_backplane-56gbit-s","pa_betriebstemperatur-40c-a-75chumidite-relative-5-a-95-sans-condensation","pa_gewicht-poids-brut-1-0-kgpois-net-0-81-kg","pa_konfiguration-interface-graphique-web-dms-snmpv1-v2c-et-v3-console-telnet-rmonles-acces-de-gestion-individuels-peuvent-etre-desactives","pa_konsolenport-1-x-rs232-rj45-1152kbit-s-8-n-1-rj45","pa_kupfer-ports-8x-10-100-1000tx-4-x-poe-4-x-poe-rj45puissance-poe-maximale-sur-tous-les-ports-360-wports-1-4-poe-et-ports-5-8-poela-puissance-maximale-des-paires-de-ports-5-6-et-7-8-e","pa_lebenszyklus-normal","pa_leistungaufnahme-max-15w-sans-poe-avec-poe","pa_lwl-ports-2x-sfp-sfp-1g-10gnous-vous-recommandons-dutiliser-nos-sfp-barox-nous-ne-verifions-pas-et-ne-garantissons-pas-la-compatibilite-de-nos-appareils-avec-les-sfp-dautres-fabricants","pa_mac-tabelle-16k","pa_sfp-datenrate-10gbit-s","pa_speisespannung-48-56-vdc","desktop-align-left","tablet-align-left","mobile-align-left","ast-product-gallery-layout-horizontal","ast-product-gallery-with-no-image","ast-magnify-disabled","ast-product-tabs-layout-horizontal","first","instock","product-type-simple"],"acf":{"zubeh_rverkn_pfung":"AC-SFP+MM-E-0.082|AC-SFP+SM-E-10|AC-SFP+SM-E-40|AC-SFP+-VKMM-10M|AC-SFP+-VKMM-1M|AC-SFP+-VKMM-5M|AC-SFP-BIA-FXME|AC-SFP-BIA-FXSE|AC-SFP-BIA-LXE|AC-SFP-BIA-SXE|AC-SFP-BIB-FXME|AC-SFP-BIB-FXSE|AC-SFP-BIB-LXE|AC-SFP-BIB-SXE|AC-SFP-FXMME|AC-SFP-FXSME|AC-SFP-LX-E-10|AC-SFP-LX-E-20|AC-SFP-LX-E-40|AC-SFP-LX-E-70|AC-SFP-SX-E|AC-SFP-SXOM3-E|PS-DIN","description":"Ce Switch robuste et de haute qualit\u00e9 est con\u00e7u pour une utilisation dans des structures de r\u00e9seau en anneau Ethernet 10, 100 et 1000MBit\/s selon IEEE802.x. Les huit ports en cuivre disposent d'une alimentation par Ethernet avec PoE, PoE+ et PoE++. Ces appareils ont \u00e9t\u00e9 sp\u00e9cialement d\u00e9velopp\u00e9s pour les r\u00e9seaux vid\u00e9o. Le Switch permet la construction d'un ou plusieurs anneaux \u00e0 tol\u00e9rance de pannes via deux ou plusieurs connexions. En cas d'interruption, l'anneau se ferme automatiquement en moins de 50ms. Cela am\u00e9liore la disponibilit\u00e9 du syst\u00e8me.Deux emplacements SFP pour 1\/10Gbit\/s sont disponibles pour le backbone, qui peuvent \u00eatre \u00e9quip\u00e9 en multimode ou monomode. Les Switches peuvent \u00e9galement \u00eatre utilis\u00e9s comme appareils autonomes, pour des connexions point \u00e0 point ou comme modules de connexion. Les possibilit\u00e9s \u00e9tendues du logiciel de gestion permettent \u00e9galement l'utilisation du Switch dans des syst\u00e8mes \u00e0 haute fonctionalit\u00e9. L'installation est tr\u00e8s facile gr\u00e2ce au dispositif de montage pour rails de montage. Les connexions \u00e9lectriques et optiques sont assur\u00e9es par des blocs d'alimentation en norme (RJ45 ou LC).","kurzbeschreibung":"Switch Industriel L2\/L3 avec management, fonctionnalit\u00e9s de s\u00e9curit\u00e9 renforc\u00e9es et ports SFP PoE ++ 10 Gbit","stichwort":"Montage sur rail DIN|Ports cuivre : 8 x10|Ports Fibre : 2 x SFP\/SFP+ 1G\/10G|Avec management, fonctions L3|Non Stop PoE|OSPFv2\/v3 und RIPv1\/v2|IEEE 1588 V2, PTP|Sans ventilateur|Alimentation 48-57VDC, redondont","lebenszyklus":"Normal","lebenszyklus_markierung":"","end_of_life_info":"","lifecycle_datei":"","besonderheit_f_r_videonetzwerke":"<strong><strong>Surveillance active de la cam\u00e9ra<\/strong><\/strong><br \/>Les cam\u00e9ras aliment\u00e9es par le Switch via PoE sont surveill\u00e9es en permanence. En cas de panne de la cam\u00e9ra, le Switch red\u00e9marre automatiquement la cam\u00e9ra. En cas d'\u00e9chec, le Switch envoie un message d'alarme via SNMP.<br \/><br \/><strong><strong>Surveillance active de l'alimentation PoE<\/strong><\/strong><br \/>Si, par exemple, une cam\u00e9ra d\u00e9fectueuse consomme trop d'alimentation de la part du Switch, ce dernier \u00e9met une alerte via SNMP.<br \/><br \/><strong><strong>Gestion active de la performance des PoE<\/strong><\/strong><br \/>Lorsque le Switch est d\u00e9marr\u00e9, les ports PoE individuels peuvent \u00eatre d\u00e9marr\u00e9s avec un d\u00e9calage temporaire pour \u00e9viter une surcharge de l'alimentation PoE.<br \/><br \/><strong><strong>Fonctionnalit\u00e9s suppl\u00e9mentaires compatibles avec la vid\u00e9o<\/strong><\/strong><br \/>Performances de backplane tr\u00e8s \u00e9lev\u00e9e pour une transmission vid\u00e9o fluide m\u00eame \u00e0 pleine charge des ports. Les frames Jumbo jusqu'\u00e0 9600Bytes sont \u00e9galement support\u00e9es \u00e0 100MBit\/s. S\u00e9curit\u00e9 du port par restriction d'adresses MAC.","dms":"<h4>DMS (Device Management System)<br \/><br \/><\/h4><br><p><strong><strong>Aper\u00e7u graphique du r\u00e9seau<\/strong><\/strong><br \/>La repr\u00e9sentation de la topologie du r\u00e9seau permet un aper\u00e7u de tous les Switch et terminaux disponibles dans le r\u00e9seau, tels que les cam\u00e9ras IP ou les serveurs, avec des d\u00e9tails sur l'adresse IP, le type de p\u00e9riph\u00e9rique et le nom. Des plans et des cartes geographiques peuvent \u00eatre d\u00e9finis comme images de fond, ce qui permet \u00e0 l'utilisateur d'acc\u00e9der rapidement \u00e0 certains p\u00e9riph\u00e9riques r\u00e9seau m\u00eame sans connaissances profondes de la structure IP.<br \/><br \/><strong><strong>Recherche de dispositif<\/strong><\/strong><\/p><br><p>Cette fonction permet d'acc\u00e9der \u00e0 un appareil sp\u00e9cifique m\u00eame dans les grands r\u00e9seaux. Les p\u00e9riph\u00e9riques recemment ajout\u00e9s, par exemple une cam\u00e9ra IP remplac\u00e9e, sont affich\u00e9s imm\u00e9diatement et permettent \u00e0 l'utilisateur d'y acc\u00e9der imm\u00e9diatement sans conna\u00eetre l'adresse IP.<br \/><br \/><strong><strong>Affichage du trafic de donn\u00e9es<\/strong><\/strong><br \/>Le trafic de donn\u00e9es par port peut \u00eatre repr\u00e9sent\u00e9 graphiquement sur un axe de temps.<br \/><br \/><strong><strong>Gestion des erreurs et s\u00e9curit\u00e9<\/strong><\/strong><br \/>Diagnostic de r\u00e9seau entre l'interrupteur principal et les bornes connect\u00e9es.<br \/>Des m\u00e9canismes de protection tels que la limitation du d\u00e9bit de donn\u00e9es offrent une protection efficace contre les acc\u00e8s non d\u00e9sir\u00e9s.<br \/>IEEE802.3ah et IEEE802.1ag fournissent des outils pour structurer les r\u00e9seaux.<\/p>","spezielle_eigenschaften":"Le switch dispose de fonctions de s\u00e9curit\u00e9 \u00e9tendues. Par exemple, l'ACL permet de prot\u00e9ger non seulement le commutateur lui-m\u00eame, mais \u00e9galement le trafic sur le r\u00e9seau.<br \/>Non-Stop PoE : Lorsque le switch est red\u00e9marr\u00e9, l'alimentation PoE des cam\u00e9ras connect\u00e9es n'est pas interrompue. D\u00e8s que l'interrupteur est \u00e0 nouveau fonctionnel, les images de la cam\u00e9ra le sont \u00e9galement.","systemhinweise":"Le switch prend en charge PTP, protocole de temps de pr\u00e9cision selon IEEE1588 v2 et IEC 61588. Cette fonction est utilis\u00e9e, entre autres, dans l'automatisation industrielle, dans les applications audio-vid\u00e9o professionnelles pour le pontage audio-vid\u00e9o et dans les t\u00e9l\u00e9communications.<br \/>Le switch prend \u00e9galement en charge les protocoles de routage dynamique OSPFv2\/v3 et RIPv1\/v2.<br \/>S-VLAN peut \u00eatre utilis\u00e9 pour la structure VLAN avec les fournisseurs de services.","tipps_tricks":"","kupfer_ports":"8x 10\/100\/1000TX, 4 x PoE+, 4 x PoE++, RJ45<br \/>Puissance PoE maximale sur tous les ports\u00a0: 360\u00a0W<br \/>Ports 1-4 PoE+ et ports 5-8 PoE++<br \/>La puissance maximale des paires de ports 5-6 et 7-8 est de 120W par paire. Cela signifie que si <br \/>par exemple 90W sont mis \u00e0 disposition sur le port 5, 30W maximum sont encore disponibles pour le port 6.<br \/>","extender_ports":"","bertragungskabel":"","distanzangabe":"","lwl_ports":"2x SFP\/SFP+, 1G\/10G<br \/>Nous vous recommandons d'utiliser nos SFP barox. Nous ne v\u00e9rifions pas et ne garantissons pas la compatibilit\u00e9 de nos appareils avec les SFP d'autres fabricants.","uplink_ports":"","konsolenport":"1 x RS232, RJ45 \/\u00a0115,2kBit\/s, 8, N, 1, RJ45","serielle_schittstelle":"","schaltkontakt":"","e1_schnittstelle":"","telefonie_schnittstelle":"","videoschnittstelle":"","video_aufl_sung":"","audio_schnittstelle":"","speisespannung":"48 -56 VDC<br \/>","leistungaufnahme":"Max. 15W (sans PoE) \/ (avec PoE)","ip_schutzart":"","mtbf":"25\u00b0C: 188'146h<br \/>50\u00b0C: 59'932h","betriebstemperatur":"-40\u00b0C \u00e0 +75\u00b0C<br \/>Humidit\u00e9 relative: 5% \u00e0 95%, sans condensation<br \/>","verlustleistung":"","abmessungen":"170x70x130mm (HxBxL)","gewicht":"Poids brut: 1.0 kg<br\/>Pois net: 0.81 kg","pr_fnormen":"","management":"","backplane":"56GBit\/s","mac_tabelle":"16k","konfiguration":"<p>Interface graphique Web, DMS, SNMPv1, v2c et v3, console, Telnet, RMON<br \/>Les acc\u00e8s de gestion individuels peuvent \u00eatre d\u00e9sactiv\u00e9s<\/p>","poe_management":"<strong>Configuration des ports<\/strong><br \/>Prise en charge de la fonction de configuration PoE par port.<br \/><br \/><strong>Planification PoE<\/strong><br \/>Prend en charge la planification PoE par port pour activer\/d\u00e9sactiver les p\u00e9riph\u00e9riques PoE (PD).<br \/><br \/><strong>V\u00e9rification automatique<\/strong><br \/>V\u00e9rification de l'\u00e9tat de connexion des PD. Red\u00e9marrez les PD s'il n'y a pas de r\u00e9ponse.<br \/><br \/><strong>Retard de performances<\/strong><br \/>Les ports PoE peuvent \u00eatre activ\u00e9s avec une temporisation pour prot\u00e9ger le commutateur contre les surcharges.<br \/><strong><br \/>PoE non-stop, red\u00e9marrage en douceur<\/strong><br \/>Le commutateur alimente \u00e9galement les PD pendant le red\u00e9marrage en douceur.","porteinstellungen":"Port d\u00e9sactiv\u00e9\/activ\u00e9, n\u00e9gociation automatique 10\/100\/100\/1000 Mbps et 10Gbps, contr\u00f4le de flux d\u00e9sactiv\u00e9\/activ\u00e9, contr\u00f4le du d\u00e9bit de donn\u00e9es sur chaque port, taille de trame max., contr\u00f4le de l'alimentation","port_statusanzeige":"Affichage par port\u00a0: vitesse, \u00e9tat de la liaison, \u00e9tat du contr\u00f4le de flux, \u00e9tat de l'auton\u00e9gociation, \u00e9tat du tronc<br \/>Commutable sur l'affichage de l'\u00e9tat PoE","layer3_funktionen":"IPv4 et IPv6\u00a0: routage statique et dynamique<br \/>OSPFv2\/v3 \/ RIPv1\/v2","kommunikationsredundanz":"Standard Spanning Tree (STP), IEEE802.1d<br \/>Rapid Spanning Tree (RSTP), IEEE802.w<br \/>Multiple Spanning Tree (MSTP), IEEE802.1s<br \/>Ethernet Linear Protection Switching (ELPS), ITU-T G.8031<br \/>Ethernet Ring Protection Switching, (ERPS), ITU-T G.8032","vlan":"<strong>VLAN bas\u00e9 sur des balises selon 802.1Q<\/strong><br \/>Prend en charge jusqu'\u00e0 4K VLAN simultan\u00e9ment (sur 4096 ID VLAN)<br \/><br \/><strong>VLAN bas\u00e9 sur les ports<\/strong><br \/>Un membre de port d'un VLAN peut \u00eatre isol\u00e9 d'autres ports isol\u00e9s du m\u00eame VLAN et de VLAN priv\u00e9s.<br \/><br \/><strong>P\u00e9riph\u00e9rie de VLAN priv\u00e9 (PVE)<\/strong><br \/>Les VLAN priv\u00e9s sont bas\u00e9s sur le masque de port source et il n'y a aucune connexion aux VLAN. Cela signifie que les ID de VLAN et les ID de VLAN priv\u00e9s peuvent \u00eatre identiques.<br \/><br \/><strong>VLAN voix<\/strong><br \/>La fonction Voice VLAN permet de transf\u00e9rer le trafic vocal sur le Voice VLAN.<br \/><br \/><strong>VLAN invit\u00e9<\/strong><br \/>Avec la fonction VLAN invit\u00e9 IEEE 802.1X, un VLAN invit\u00e9 peut \u00eatre configur\u00e9 pour chaque port 802.1X sur l'appareil afin de fournir des services limit\u00e9s aux clients non conformes \u00e0 la norme 802.1X.<br \/><br \/><strong>VLAN Q-in-Q (double balise)<\/strong><br \/>Cela vous permet de d\u00e9finir des exigences sp\u00e9cifiques pour les ID de VLAN et le nombre de VLAN \u00e0 prendre en charge.<br \/><br \/><strong>VLAN protocole 802.1v<\/strong><br \/>La classification de plusieurs protocoles dans un seul VLAN impose souvent des limites de VLAN qui sont inappropri\u00e9es pour certains des protocoles. Cela n\u00e9cessite l'existence d'une entit\u00e9 non standard qui transmet les trames entre les VLAN en utilisant les protocoles pour lesquels les limites des VLAN sont inappropri\u00e9es.<br \/><br \/><strong>VLAN bas\u00e9 sur MAC<\/strong><br \/>La fonction VLAN bas\u00e9e sur MAC permet d'attribuer des paquets non marqu\u00e9s entrants \u00e0 un VLAN, ce qui permet de classer le trafic en fonction de l'adresse MAC source du paquet.<br \/><br \/><strong>VLAN bas\u00e9 sur un sous-r\u00e9seau IP<\/strong><br \/>Dans un VLAN bas\u00e9 sur un sous-r\u00e9seau IP, tous les postes de travail finaux d'un sous-r\u00e9seau IP sont affect\u00e9s au m\u00eame VLAN. Ce VLAN permet aux utilisateurs de d\u00e9placer leurs postes de travail sans avoir \u00e0 reconfigurer leurs adresses r\u00e9seau.<br \/><br \/><strong>S-VLAN<\/strong><br \/>S-VLAN bas\u00e9 sur QinQ.<br \/><br \/><strong>VLAN de gestion<\/strong><br \/>Le VLAN de gestion est utilis\u00e9 pour g\u00e9rer le commutateur \u00e0 distance \u00e0 l'aide de protocoles tels que Telnet, SSH, SNMP, Syslog, etc.","link_aggregation":"IEEE 802.3ad LACP \/ Static Trunk, prend en charge cinq groupes de troncs \u00e0 16 ports ou tronc statique.","qos":"<strong>File d'attente mat\u00e9rielle<\/strong><br \/>Prend en charge huit files d'attente mat\u00e9rielles.<br \/><br \/><strong>Classification<\/strong><br \/>Bas\u00e9 sur le port\u00a0: qualit\u00e9 de service du trafic par port<br \/>802.1p : La classe de service CoS QoS de couche 2 bas\u00e9e sur la priorit\u00e9 VLAN est un param\u00e8tre utilis\u00e9 dans les protocoles de donn\u00e9es et de voix pour distinguer les types de charges utiles contenues dans le paquet transmis.<br \/>Services diff\u00e9renci\u00e9s bas\u00e9s sur DSCP (DiffServ) DSCP-QoS de couche 3\u00a0: les paquets IP peuvent transporter soit une valeur de priorit\u00e9 IP (IPP), soit une valeur DSCP (Differentiated Services Code Point). QoS prend en charge l'utilisation des deux valeurs puisque les valeurs DSCP sont r\u00e9trocompatibles avec les valeurs de priorit\u00e9 IP.<br \/>Classification et re-marquage des ACL TCP\/IP : QoS par ACL<br \/><br \/><strong>Limitation de d\u00e9bit<\/strong><br \/>agent de police d'entr\u00e9e<br \/>Mise en forme de sortie et contr\u00f4le du d\u00e9bit par port<br \/><br \/><strong>Planification<\/strong><br \/>Priorit\u00e9 stricte et Round Robin pond\u00e9r\u00e9 (WRR) : Weighted Round Robin est un algorithme de planification qui utilise les pond\u00e9rations attribu\u00e9es aux files d'attente pour d\u00e9terminer la quantit\u00e9 de donn\u00e9es \u00e0 vider d'une file d'attente avant de passer \u00e0 la file d'attente suivante.","security":"<p><strong>Authentification certifi\u00e9e<\/strong><br \/>Une cl\u00e9 HTTPS priv\u00e9e peut \u00eatre stock\u00e9e pour l'acc\u00e8s de gestion.<br \/><br \/><strong>Gestion des utilisateurs<\/strong><br \/>Les droits d'utilisateur peuvent \u00eatre d\u00e9finis librement jusqu'\u00e0 15 niveaux.<br \/><br \/><strong>ACL<\/strong><br \/>Le commutateur permet jusqu'\u00e0 512 entr\u00e9es. Limite d'abandon ou de d\u00e9bit bas\u00e9e sur l'adresse MAC\/IP source\/destination ou l'ID VLAN. Les r\u00e8gles et conditions pour les paquets entrants peuvent \u00eatre d\u00e9finies par port. Les r\u00e8gles incluent les protocoles, les ports IP et les plages d'adresses. Les r\u00e8gles peuvent \u00eatre fix\u00e9es soit selon la proc\u00e9dure d'autorisation, soit selon la proc\u00e9dure d'exclusion. Les crit\u00e8res sont : Ports source et destination TCP\/UDP, priorit\u00e9 802.1p, type Ethernet, paquet ICMP (Internet Control Message Protocol).<br \/><br \/><strong>S\u00e9curit\u00e9 portuaire<br \/><\/strong>Gestion de l'adresse MAC par port et protection de source IP : L'adresse MAC peut \u00eatre v\u00e9rifi\u00e9e en combinaison avec l'adresse IP.<br \/><strong><br \/>Contr\u00f4le des temp\u00eates<br \/><\/strong>Emp\u00eache le trafic sur un r\u00e9seau local d'\u00eatre interrompu par une inondation de diffusion, de multidiffusion ou de monodiffusion sur un port.<strong><br \/><br \/>Authentification RADIUS, 802.1X<br \/><\/strong>Autorisation et comptabilit\u00e9, hachage MD5, VLAN invit\u00e9, mode h\u00f4te unique\/multiple et sessions uniques\/multiples<br \/>Prend en charge 802.1X bas\u00e9 sur IGMP RADIUS<br \/>Affectation VLAN dynamique<strong><br \/><br \/>Authentification TACACS+<br \/><\/strong>Le commutateur prend en charge l'authentification TACACS+. passer en tant que client.<strong><br \/><br \/>Coquille s\u00e9curis\u00e9e (SSH)<br \/><\/strong>SSH s\u00e9curise le trafic Telnet entrant ou sortant du commutateur, SSH v1 et v2 sont pris en charge<br \/><strong><br \/>Couche de sockets s\u00e9curis\u00e9e (SSL)<br \/><\/strong>SSL crypte le trafic HTTP, permettant un acc\u00e8s s\u00e9curis\u00e9 am\u00e9lior\u00e9 \u00e0 l'interface graphique de gestion bas\u00e9e sur un navigateur dans le commutateur.<strong><br \/><br \/>HTTPS & SSL (Web s\u00e9curis\u00e9)<br \/><\/strong>Hyper Text Transfer Protocol Secure (HTTPS) est la version s\u00e9curis\u00e9e de HTTP.<strong><br \/><br \/>Garde BPDU<br \/><\/strong>Le BPDU Guardian, une extension de STP, supprime un n\u0153ud qui renvoie les BPDU dans le r\u00e9seau. Il applique les limites du domaine STP et maintient la topologie active pr\u00e9visible en n'autorisant aucun p\u00e9riph\u00e9rique r\u00e9seau derri\u00e8re un port activ\u00e9 par BPDU Guard \u00e0 participer \u00e0 STP.<strong><br \/><br \/>Surveillance DHCP<br \/><\/strong>Avec la surveillance DHCP, le commutateur dispose d'une fonctionnalit\u00e9 qui agit comme un pare-feu entre les h\u00f4tes non approuv\u00e9s et les serveurs DHCP approuv\u00e9s.<strong><br \/><br \/>Protection de boucle<br \/><\/strong>La protection contre les boucles emp\u00eache les boucles monodiffusion, diffusion et multidiffusion inconnues dans les configurations de commutation de couche 2.<\/p>","multicast":"<strong>Surveillance IGMP v1\/v2\/v3<\/strong><br \/>IGMP limite le trafic multicast gourmand en bande passante aux candidats. Prend en charge 1024 groupes de multidiffusion.<br \/><br \/><strong>Interrogateur IGMP<\/strong><br \/>IGMP Querier est utilis\u00e9 par les commutateurs de surveillance pour prendre en charge un domaine de multidiffusion de couche 2 lorsqu'aucun routeur de multidiffusion n'est pr\u00e9sent.<br \/><br \/><strong>Proxy IGMP<\/strong><br \/>La surveillance IGMP avec rapport proxy ou suppression de rapport filtre activement les paquets IGMP pour r\u00e9duire la charge sur le routeur multidiffusion.<br \/><br \/><strong>Espionnage MLD v1\/v2<\/strong><br \/>Fournit les paquets de multidiffusion IPv6 uniquement aux destinataires requis.<br \/><br \/><strong>Enregistrement VLAN multidiffusion (MVR)<\/strong><br \/>Un VLAN d\u00e9di\u00e9 et configur\u00e9 manuellement, appel\u00e9 VLAN de multidiffusion, pour transf\u00e9rer le trafic de multidiffusion sur un r\u00e9seau de couche 2 en conjonction avec la surveillance IGMP.","topologie":"","normen":"IEEE 802.3 10Base-T<br>IEEE 802.3u 100Base-TX\/100BASE-FX<br>IEEE 802.3z Gigabit SX\/LX<br>IEEE 802.3ab Gigabit 1000T<br>IEEE 802.3x Flow Control and Back pressure<br>IEEE 802.3ad Port trunk with LACP<br>IEEE 802.1d Spanning tree protocol<br>IEEE 802.1w Rapid spanning tree protocol<br>IEEE 802.1s Multiple spanning tree protocol<br>IEEE 802.1p Class ofservice<br>IEEE 802.1Q VLAN Tagging<br>IEEE 802.1x Port Authentication Network Control<br>IEEE 802.1ab LLDP<br>IEEE 802.3af\/at\/bt Power over Ethernet<br>IEEE 802.az Energy Efficient Ethernet<br>IEEE 1588v2 PTP Precisison Time Protocol","dienste":"","fasertyp_leitertyp":"","faserzahl":"","datenrate":"","bertragungsdistanz_max":"","stecker":"","zentrumswellenl_nge_rx":"","zentrumswellenl_nge_tx":"","min_optische_sendeleistung":"","max_optische_sendeleistung":"","opt_empfindlichkeit":"","max_optische_eingangsleistung":"","optisches_budget":"","streckend_mpfung_min":"","bilddatei":"RY-LPITE-442XGBME.png","galerie_bilddateien":"","manual_datei":"","ce_coc_datei":"RY-LPITE-442XGME, CE Konformit\u00e4tserkl\u00e4rung.pdf|UL-CoC, RY-01.pdf|RY-LPITE-442XGME_FCC.pdf","cad_datei":"RY-LPITE-442XGBME.DXF","visio_datei":"2026-05-18, Shapes RY-Switches & LT-LPITE-402.zip","lv_text_datei":"","schema_dateien":"","fw_aktuell_dateien":"","fw_archiv_dateien":"","fw_cve_datei":"","fw_release_notes":"","fw_release_archiv":"","foss_dokumentation":"","weitere_downloads":"","filter_sfp_faserart":"","filter_sfp_faserzahl":"","filter_sfp_datenrate":"10GBit\/s","spalte1":"","f_montage_keine_angabe":"","f_montage_19":"","f_montage_hutschienenmontage":"x","f_montage_tisch_oder_wandmontage":"","f_poe_kein_poe":"","f_poe_poe_af_15w":"x","f_poe_poe_at_30w":"x","f_poe_poe_60w":"x","f_poe_poe_bt_90w":"x","f_manage_management":"x","f_manage_kein_management":"","f_extend_utp":"","f_extend_coax":"","f_extend_fiber":"","f_speisung_5vdc":"","f_speisung_12vdc":"","f_speisung_24vdc":"","f_speisung_48vdc":"x","f_speisung_110_230vac":"","f_speisung_poe":"","f_speisung_redundant":"x","sw_tools":"","pdf_link":"https:\/\/products.barox.ch\/?pdf=ry-lpite-442xgme"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>RY-LPITE-442XGME | Switches | barox<\/title>\n<meta name=\"description\" content=\"RY-LPITE-442XGME - Switches: Montage sur rail DIN|Ports cuivre : 8 x10|Ports Fibre : 2 x SFP\/SFP+ 1G\/10G|Avec management, fonctions L3|Non Stop PoE|OSPFv2\/v3 und RIPv1\/v2|IEEE 1588 V2, PTP|Sans ventilateur|Alimentation 48-57VDC, redondont\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/products.barox.ch\/fr\/produits\/switches\/ry-lpite-442xgme\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"RY-LPITE-442XGME | Switches | barox\" \/>\n<meta property=\"og:description\" content=\"RY-LPITE-442XGME - Switches: Montage sur rail DIN|Ports cuivre : 8 x10|Ports Fibre : 2 x SFP\/SFP+ 1G\/10G|Avec management, fonctions L3|Non Stop PoE|OSPFv2\/v3 und RIPv1\/v2|IEEE 1588 V2, PTP|Sans ventilateur|Alimentation 48-57VDC, redondont\" \/>\n<meta property=\"og:url\" content=\"https:\/\/products.barox.ch\/fr\/produits\/switches\/ry-lpite-442xgme\/\" \/>\n<meta property=\"og:site_name\" content=\"Produkte Shop Barox\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-16T15:20:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME.png\" \/>\n\t<meta property=\"og:image:width\" content=\"211\" \/>\n\t<meta property=\"og:image:height\" content=\"409\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":[\"WebPage\",\"ItemPage\"],\"@id\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/produits\\\/switches\\\/ry-lpite-442xgme\\\/\",\"url\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/produits\\\/switches\\\/ry-lpite-442xgme\\\/\",\"name\":\"RY-LPITE-442XGME | Switches | barox\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/produits\\\/switches\\\/ry-lpite-442xgme\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/produits\\\/switches\\\/ry-lpite-442xgme\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/products.barox.ch\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/RY-LPITE-442XGBME.png\",\"datePublished\":\"2026-06-16T15:20:25+00:00\",\"dateModified\":\"2026-06-16T15:20:34+00:00\",\"description\":\"RY-LPITE-442XGME - Switches: Montage sur rail DIN|Ports cuivre : 8 x10|Ports Fibre : 2 x SFP\\\/SFP+ 1G\\\/10G|Avec management, fonctions L3|Non Stop PoE|OSPFv2\\\/v3 und RIPv1\\\/v2|IEEE 1588 V2, PTP|Sans ventilateur|Alimentation 48-57VDC, redondont\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/produits\\\/switches\\\/ry-lpite-442xgme\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/products.barox.ch\\\/fr\\\/produits\\\/switches\\\/ry-lpite-442xgme\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/produits\\\/switches\\\/ry-lpite-442xgme\\\/#primaryimage\",\"url\":\"https:\\\/\\\/products.barox.ch\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/RY-LPITE-442XGBME.png\",\"contentUrl\":\"https:\\\/\\\/products.barox.ch\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/RY-LPITE-442XGBME.png\",\"width\":211,\"height\":409},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/produits\\\/switches\\\/ry-lpite-442xgme\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Page d'accueil\",\"item\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Produits\",\"item\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"RY-LPITE-442XGME\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/\",\"name\":\"barox products\",\"description\":\"Websamurai for Gutenberg\",\"publisher\":{\"@id\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/#organization\"},\"alternateName\":\"barox Kommunikation AG\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/#organization\",\"name\":\"barox products\",\"alternateName\":\"barox Kommunikation AG\",\"url\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/products.barox.ch\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/barox-kommunikation-ag@696x696-1.png\",\"contentUrl\":\"https:\\\/\\\/products.barox.ch\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/barox-kommunikation-ag@696x696-1.png\",\"width\":696,\"height\":696,\"caption\":\"barox products\"},\"image\":{\"@id\":\"https:\\\/\\\/products.barox.ch\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/ch.linkedin.com\\\/company\\\/barox-kommunikation-ag\",\"https:\\\/\\\/www.youtube.com\\\/@baroxkommunikationag4606\"]}]}<\/script>\n<meta property=\"product:price:currency\" content=\"CHF\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:retailer_item_id\" content=\"RY-LPITE-442XGME\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"RY-LPITE-442XGME | Switches | barox","description":"RY-LPITE-442XGME - Switches: Montage sur rail DIN|Ports cuivre : 8 x10|Ports Fibre : 2 x SFP\/SFP+ 1G\/10G|Avec management, fonctions L3|Non Stop PoE|OSPFv2\/v3 und RIPv1\/v2|IEEE 1588 V2, PTP|Sans ventilateur|Alimentation 48-57VDC, redondont","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/products.barox.ch\/fr\/produits\/switches\/ry-lpite-442xgme\/","og_locale":"fr_FR","og_type":"article","og_title":"RY-LPITE-442XGME | Switches | barox","og_description":"RY-LPITE-442XGME - Switches: Montage sur rail DIN|Ports cuivre : 8 x10|Ports Fibre : 2 x SFP\/SFP+ 1G\/10G|Avec management, fonctions L3|Non Stop PoE|OSPFv2\/v3 und RIPv1\/v2|IEEE 1588 V2, PTP|Sans ventilateur|Alimentation 48-57VDC, redondont","og_url":"https:\/\/products.barox.ch\/fr\/produits\/switches\/ry-lpite-442xgme\/","og_site_name":"Produkte Shop Barox","article_modified_time":"2026-06-16T15:20:34+00:00","og_image":[{"width":211,"height":409,"url":"https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME.png","type":"image\/png"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["WebPage","ItemPage"],"@id":"https:\/\/products.barox.ch\/fr\/produits\/switches\/ry-lpite-442xgme\/","url":"https:\/\/products.barox.ch\/fr\/produits\/switches\/ry-lpite-442xgme\/","name":"RY-LPITE-442XGME | Switches | barox","isPartOf":{"@id":"https:\/\/products.barox.ch\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/products.barox.ch\/fr\/produits\/switches\/ry-lpite-442xgme\/#primaryimage"},"image":{"@id":"https:\/\/products.barox.ch\/fr\/produits\/switches\/ry-lpite-442xgme\/#primaryimage"},"thumbnailUrl":"https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME.png","datePublished":"2026-06-16T15:20:25+00:00","dateModified":"2026-06-16T15:20:34+00:00","description":"RY-LPITE-442XGME - Switches: Montage sur rail DIN|Ports cuivre : 8 x10|Ports Fibre : 2 x SFP\/SFP+ 1G\/10G|Avec management, fonctions L3|Non Stop PoE|OSPFv2\/v3 und RIPv1\/v2|IEEE 1588 V2, PTP|Sans ventilateur|Alimentation 48-57VDC, redondont","breadcrumb":{"@id":"https:\/\/products.barox.ch\/fr\/produits\/switches\/ry-lpite-442xgme\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/products.barox.ch\/fr\/produits\/switches\/ry-lpite-442xgme\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/products.barox.ch\/fr\/produits\/switches\/ry-lpite-442xgme\/#primaryimage","url":"https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME.png","contentUrl":"https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME.png","width":211,"height":409},{"@type":"BreadcrumbList","@id":"https:\/\/products.barox.ch\/fr\/produits\/switches\/ry-lpite-442xgme\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Page d'accueil","item":"https:\/\/products.barox.ch\/fr\/"},{"@type":"ListItem","position":2,"name":"Produits","item":"https:\/\/products.barox.ch\/fr\/"},{"@type":"ListItem","position":3,"name":"RY-LPITE-442XGME"}]},{"@type":"WebSite","@id":"https:\/\/products.barox.ch\/fr\/#website","url":"https:\/\/products.barox.ch\/fr\/","name":"barox products","description":"Websamurai for Gutenberg","publisher":{"@id":"https:\/\/products.barox.ch\/fr\/#organization"},"alternateName":"barox Kommunikation AG","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/products.barox.ch\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/products.barox.ch\/fr\/#organization","name":"barox products","alternateName":"barox Kommunikation AG","url":"https:\/\/products.barox.ch\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/products.barox.ch\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/barox-kommunikation-ag@696x696-1.png","contentUrl":"https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/barox-kommunikation-ag@696x696-1.png","width":696,"height":696,"caption":"barox products"},"image":{"@id":"https:\/\/products.barox.ch\/fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/ch.linkedin.com\/company\/barox-kommunikation-ag","https:\/\/www.youtube.com\/@baroxkommunikationag4606"]}]},"product_price_currency":"CHF","og_availability":"instock","product_availability":"instock","product_retailer_item_id":"RY-LPITE-442XGME","product_condition":"new"},"spectra_custom_meta":{"total_sales":["0"],"_stock_status":["instock"],"_wp_old_slug":["ry-lpite-442xgme-4"],"_wcml_average_rating":[null],"_wcml_review_count":[null],"_wcml_rating_count":[null],"_wc_review_count":["0"],"_wc_rating_count":[""],"_wc_average_rating":[0],"_sku":["RY-LPITE-442XGME"],"_tax_status":["none"],"_tax_class":[""],"_manage_stock":["no"],"_backorders":["no"],"_sold_individually":["no"],"_crosssell_ids":["a:22:{i:0;i:5928;i:1;i:5932;i:2;i:5936;i:3;i:5942;i:4;i:5945;i:5;i:5948;i:6;i:5951;i:7;i:5954;i:8;i:5957;i:9;i:5960;i:10;i:5963;i:11;i:5966;i:12;i:5969;i:13;i:5972;i:14;i:5975;i:15;i:5978;i:16;i:5981;i:17;i:5984;i:18;i:5987;i:19;i:5990;i:20;i:5993;i:21;i:5996;}"],"_virtual":["no"],"_downloadable":["no"],"_download_limit":["-1"],"_download_expiry":["-1"],"_stock":[null],"_product_attributes":["a:17:{s:16:\"pa_sfp-datenrate\";a:6:{s:4:\"name\";s:16:\"pa_sfp-datenrate\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:3;s:10:\"is_visible\";i:1;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:13:\"pa_montageart\";a:6:{s:4:\"name\";s:13:\"pa_montageart\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:4;s:10:\"is_visible\";i:1;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:6:\"pa_poe\";a:6:{s:4:\"name\";s:6:\"pa_poe\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:5;s:10:\"is_visible\";i:1;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:13:\"pa_management\";a:6:{s:4:\"name\";s:13:\"pa_management\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:6;s:10:\"is_visible\";i:1;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:11:\"pa_speisung\";a:6:{s:4:\"name\";s:11:\"pa_speisung\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:8;s:10:\"is_visible\";i:1;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:15:\"pa_lebenszyklus\";a:6:{s:4:\"name\";s:15:\"pa_lebenszyklus\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:9;s:10:\"is_visible\";i:1;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:15:\"pa_kupfer-ports\";a:6:{s:4:\"name\";s:15:\"pa_kupfer-ports\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:10;s:10:\"is_visible\";i:0;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:12:\"pa_lwl-ports\";a:6:{s:4:\"name\";s:12:\"pa_lwl-ports\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:14;s:10:\"is_visible\";i:0;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:15:\"pa_konsolenport\";a:6:{s:4:\"name\";s:15:\"pa_konsolenport\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:16;s:10:\"is_visible\";i:0;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:17:\"pa_speisespannung\";a:6:{s:4:\"name\";s:17:\"pa_speisespannung\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:17;s:10:\"is_visible\";i:0;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:19:\"pa_leistungaufnahme\";a:6:{s:4:\"name\";s:19:\"pa_leistungaufnahme\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:18;s:10:\"is_visible\";i:0;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:21:\"pa_betriebstemperatur\";a:6:{s:4:\"name\";s:21:\"pa_betriebstemperatur\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:20;s:10:\"is_visible\";i:0;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:14:\"pa_abmessungen\";a:6:{s:4:\"name\";s:14:\"pa_abmessungen\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:21;s:10:\"is_visible\";i:0;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:10:\"pa_gewicht\";a:6:{s:4:\"name\";s:10:\"pa_gewicht\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:22;s:10:\"is_visible\";i:0;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:12:\"pa_backplane\";a:6:{s:4:\"name\";s:12:\"pa_backplane\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:23;s:10:\"is_visible\";i:0;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:14:\"pa_mac-tabelle\";a:6:{s:4:\"name\";s:14:\"pa_mac-tabelle\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:24;s:10:\"is_visible\";i:0;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}s:16:\"pa_konfiguration\";a:6:{s:4:\"name\";s:16:\"pa_konfiguration\";s:5:\"value\";s:0:\"\";s:8:\"position\";i:25;s:10:\"is_visible\";i:0;s:12:\"is_variation\";i:0;s:11:\"is_taxonomy\";i:1;}}"],"_product_version":["10.8.1"],"_zubeh_rverkn_pfung":["field_zubeh_rverkn_pfung_74abf8"],"zubeh_rverkn_pfung":["AC-SFP+MM-E-0.082|AC-SFP+SM-E-10|AC-SFP+SM-E-40|AC-SFP+-VKMM-10M|AC-SFP+-VKMM-1M|AC-SFP+-VKMM-5M|AC-SFP-BIA-FXME|AC-SFP-BIA-FXSE|AC-SFP-BIA-LXE|AC-SFP-BIA-SXE|AC-SFP-BIB-FXME|AC-SFP-BIB-FXSE|AC-SFP-BIB-LXE|AC-SFP-BIB-SXE|AC-SFP-FXMME|AC-SFP-FXSME|AC-SFP-LX-E-10|AC-SFP-LX-E-20|AC-SFP-LX-E-40|AC-SFP-LX-E-70|AC-SFP-SX-E|AC-SFP-SXOM3-E|PS-DIN"],"_description":["field_description_026530"],"description":["Ce Switch robuste et de haute qualit\u00e9 est con\u00e7u pour une utilisation dans des structures de r\u00e9seau en anneau Ethernet 10, 100 et 1000MBit\/s selon IEEE802.x. Les huit ports en cuivre disposent d'une alimentation par Ethernet avec PoE, PoE+ et PoE++. Ces appareils ont \u00e9t\u00e9 sp\u00e9cialement d\u00e9velopp\u00e9s pour les r\u00e9seaux vid\u00e9o. Le Switch permet la construction d'un ou plusieurs anneaux \u00e0 tol\u00e9rance de pannes via deux ou plusieurs connexions. En cas d'interruption, l'anneau se ferme automatiquement en moins de 50ms. Cela am\u00e9liore la disponibilit\u00e9 du syst\u00e8me.Deux emplacements SFP pour 1\/10Gbit\/s sont disponibles pour le backbone, qui peuvent \u00eatre \u00e9quip\u00e9 en multimode ou monomode. Les Switches peuvent \u00e9galement \u00eatre utilis\u00e9s comme appareils autonomes, pour des connexions point \u00e0 point ou comme modules de connexion. Les possibilit\u00e9s \u00e9tendues du logiciel de gestion permettent \u00e9galement l'utilisation du Switch dans des syst\u00e8mes \u00e0 haute fonctionalit\u00e9. L'installation est tr\u00e8s facile gr\u00e2ce au dispositif de montage pour rails de montage. Les connexions \u00e9lectriques et optiques sont assur\u00e9es par des blocs d'alimentation en norme (RJ45 ou LC)."],"_kurzbeschreibung":["field_kurzbeschreibung_cfbf1d"],"kurzbeschreibung":["Switch Industriel L2\/L3 avec management, fonctionnalit\u00e9s de s\u00e9curit\u00e9 renforc\u00e9es et ports SFP PoE ++ 10 Gbit"],"_stichwort":["field_stichwort_7498d4"],"stichwort":["Montage sur rail DIN|Ports cuivre : 8 x10|Ports Fibre : 2 x SFP\/SFP+ 1G\/10G|Avec management, fonctions L3|Non Stop PoE|OSPFv2\/v3 und RIPv1\/v2|IEEE 1588 V2, PTP|Sans ventilateur|Alimentation 48-57VDC, redondont"],"_lebenszyklus":["field_lebenszyklus_0ff766"],"lebenszyklus":["Normal"],"_lebenszyklus_markierung":["field_lebenszyklus_markierung_df8ca6"],"lebenszyklus_markierung":[""],"_end_of_life_info":["field_end_of_life_info_ef427d"],"end_of_life_info":[""],"_lifecycle_datei":["field_lifecycle_datei_7777c2"],"lifecycle_datei":[""],"_besonderheit_f_r_videonetzwerke":["field_besonderheit_f_r_videonetzwerke_707b52"],"besonderheit_f_r_videonetzwerke":["<strong><strong>Surveillance active de la cam\u00e9ra<\/strong><\/strong><br \/>Les cam\u00e9ras aliment\u00e9es par le Switch via PoE sont surveill\u00e9es en permanence. En cas de panne de la cam\u00e9ra, le Switch red\u00e9marre automatiquement la cam\u00e9ra. En cas d'\u00e9chec, le Switch envoie un message d'alarme via SNMP.<br \/><br \/><strong><strong>Surveillance active de l'alimentation PoE<\/strong><\/strong><br \/>Si, par exemple, une cam\u00e9ra d\u00e9fectueuse consomme trop d'alimentation de la part du Switch, ce dernier \u00e9met une alerte via SNMP.<br \/><br \/><strong><strong>Gestion active de la performance des PoE<\/strong><\/strong><br \/>Lorsque le Switch est d\u00e9marr\u00e9, les ports PoE individuels peuvent \u00eatre d\u00e9marr\u00e9s avec un d\u00e9calage temporaire pour \u00e9viter une surcharge de l'alimentation PoE.<br \/><br \/><strong><strong>Fonctionnalit\u00e9s suppl\u00e9mentaires compatibles avec la vid\u00e9o<\/strong><\/strong><br \/>Performances de backplane tr\u00e8s \u00e9lev\u00e9e pour une transmission vid\u00e9o fluide m\u00eame \u00e0 pleine charge des ports. Les frames Jumbo jusqu'\u00e0 9600Bytes sont \u00e9galement support\u00e9es \u00e0 100MBit\/s. S\u00e9curit\u00e9 du port par restriction d'adresses MAC."],"_dms":["field_dms_072bc2"],"dms":["<h4>DMS (Device Management System)<br \/><br \/><\/h4><br><p><strong><strong>Aper\u00e7u graphique du r\u00e9seau<\/strong><\/strong><br \/>La repr\u00e9sentation de la topologie du r\u00e9seau permet un aper\u00e7u de tous les Switch et terminaux disponibles dans le r\u00e9seau, tels que les cam\u00e9ras IP ou les serveurs, avec des d\u00e9tails sur l'adresse IP, le type de p\u00e9riph\u00e9rique et le nom. Des plans et des cartes geographiques peuvent \u00eatre d\u00e9finis comme images de fond, ce qui permet \u00e0 l'utilisateur d'acc\u00e9der rapidement \u00e0 certains p\u00e9riph\u00e9riques r\u00e9seau m\u00eame sans connaissances profondes de la structure IP.<br \/><br \/><strong><strong>Recherche de dispositif<\/strong><\/strong><\/p><br><p>Cette fonction permet d'acc\u00e9der \u00e0 un appareil sp\u00e9cifique m\u00eame dans les grands r\u00e9seaux. Les p\u00e9riph\u00e9riques recemment ajout\u00e9s, par exemple une cam\u00e9ra IP remplac\u00e9e, sont affich\u00e9s imm\u00e9diatement et permettent \u00e0 l'utilisateur d'y acc\u00e9der imm\u00e9diatement sans conna\u00eetre l'adresse IP.<br \/><br \/><strong><strong>Affichage du trafic de donn\u00e9es<\/strong><\/strong><br \/>Le trafic de donn\u00e9es par port peut \u00eatre repr\u00e9sent\u00e9 graphiquement sur un axe de temps.<br \/><br \/><strong><strong>Gestion des erreurs et s\u00e9curit\u00e9<\/strong><\/strong><br \/>Diagnostic de r\u00e9seau entre l'interrupteur principal et les bornes connect\u00e9es.<br \/>Des m\u00e9canismes de protection tels que la limitation du d\u00e9bit de donn\u00e9es offrent une protection efficace contre les acc\u00e8s non d\u00e9sir\u00e9s.<br \/>IEEE802.3ah et IEEE802.1ag fournissent des outils pour structurer les r\u00e9seaux.<\/p>"],"_spezielle_eigenschaften":["field_spezielle_eigenschaften_ad883f"],"spezielle_eigenschaften":["Le switch dispose de fonctions de s\u00e9curit\u00e9 \u00e9tendues. Par exemple, l'ACL permet de prot\u00e9ger non seulement le commutateur lui-m\u00eame, mais \u00e9galement le trafic sur le r\u00e9seau.<br \/>Non-Stop PoE : Lorsque le switch est red\u00e9marr\u00e9, l'alimentation PoE des cam\u00e9ras connect\u00e9es n'est pas interrompue. D\u00e8s que l'interrupteur est \u00e0 nouveau fonctionnel, les images de la cam\u00e9ra le sont \u00e9galement."],"_systemhinweise":["field_systemhinweise_f9500c"],"systemhinweise":["Le switch prend en charge PTP, protocole de temps de pr\u00e9cision selon IEEE1588 v2 et IEC 61588. Cette fonction est utilis\u00e9e, entre autres, dans l'automatisation industrielle, dans les applications audio-vid\u00e9o professionnelles pour le pontage audio-vid\u00e9o et dans les t\u00e9l\u00e9communications.<br \/>Le switch prend \u00e9galement en charge les protocoles de routage dynamique OSPFv2\/v3 et RIPv1\/v2.<br \/>S-VLAN peut \u00eatre utilis\u00e9 pour la structure VLAN avec les fournisseurs de services."],"_tipps_tricks":["field_tipps_tricks_4303a6"],"tipps_tricks":[""],"_kupfer_ports":["field_kupfer_ports_c4c169"],"kupfer_ports":["8x 10\/100\/1000TX, 4 x PoE+, 4 x PoE++, RJ45<br \/>Puissance PoE maximale sur tous les ports\u00a0: 360\u00a0W<br \/>Ports 1-4 PoE+ et ports 5-8 PoE++<br \/>La puissance maximale des paires de ports 5-6 et 7-8 est de 120W par paire. Cela signifie que si <br \/>par exemple 90W sont mis \u00e0 disposition sur le port 5, 30W maximum sont encore disponibles pour le port 6.<br \/>"],"_extender_ports":["field_extender_ports_03210d"],"extender_ports":[""],"_bertragungskabel":["field_bertragungskabel_d11caf"],"bertragungskabel":[""],"_distanzangabe":["field_distanzangabe_238fbb"],"distanzangabe":[""],"_lwl_ports":["field_lwl_ports_ac56e1"],"lwl_ports":["2x SFP\/SFP+, 1G\/10G<br \/>Nous vous recommandons d'utiliser nos SFP barox. Nous ne v\u00e9rifions pas et ne garantissons pas la compatibilit\u00e9 de nos appareils avec les SFP d'autres fabricants."],"_uplink_ports":["field_uplink_ports_6cce13"],"uplink_ports":[""],"_konsolenport":["field_konsolenport_c7ac95"],"konsolenport":["1 x RS232, RJ45 \/\u00a0115,2kBit\/s, 8, N, 1, RJ45"],"_serielle_schittstelle":["field_serielle_schittstelle_020d7c"],"serielle_schittstelle":[""],"_schaltkontakt":["field_schaltkontakt_383d10"],"schaltkontakt":[""],"_e1_schnittstelle":["field_e1_schnittstelle_33594a"],"e1_schnittstelle":[""],"_telefonie_schnittstelle":["field_telefonie_schnittstelle_bd79c0"],"telefonie_schnittstelle":[""],"_videoschnittstelle":["field_videoschnittstelle_53735e"],"videoschnittstelle":[""],"_video_aufl_sung":["field_video_aufl_sung_a79262"],"video_aufl_sung":[""],"_audio_schnittstelle":["field_audio_schnittstelle_4471ed"],"audio_schnittstelle":[""],"_speisespannung":["field_speisespannung_577b9d"],"speisespannung":["48 -56 VDC<br \/>"],"_leistungaufnahme":["field_leistungaufnahme_44c478"],"leistungaufnahme":["Max. 15W (sans PoE) \/ (avec PoE)"],"_ip_schutzart":["field_ip_schutzart_d5a3ed"],"ip_schutzart":[""],"_mtbf":["field_mtbf_31abbc"],"mtbf":["25\u00b0C: 188'146h<br \/>50\u00b0C: 59'932h"],"_betriebstemperatur":["field_betriebstemperatur_cacefe"],"betriebstemperatur":["-40\u00b0C \u00e0 +75\u00b0C<br \/>Humidit\u00e9 relative: 5% \u00e0 95%, sans condensation<br \/>"],"_verlustleistung":["field_verlustleistung_743044"],"verlustleistung":[""],"_abmessungen":["field_abmessungen_d01eb8"],"abmessungen":["170x70x130mm (HxBxL)"],"_gewicht":["field_gewicht_4b1ee9"],"gewicht":["Poids brut: 1.0 kg<br\/>Pois net: 0.81 kg"],"_pr_fnormen":["field_pr_fnormen_5679bc"],"pr_fnormen":[""],"_management":["field_management_b94603"],"management":[""],"_backplane":["field_backplane_11e7ed"],"backplane":["56GBit\/s"],"_mac_tabelle":["field_mac_tabelle_ebc253"],"mac_tabelle":["16k"],"_konfiguration":["field_konfiguration_7fb20b"],"konfiguration":["<p>Interface graphique Web, DMS, SNMPv1, v2c et v3, console, Telnet, RMON<br \/>Les acc\u00e8s de gestion individuels peuvent \u00eatre d\u00e9sactiv\u00e9s<\/p>"],"_poe_management":["field_poe_management_b9e20b"],"poe_management":["<strong>Configuration des ports<\/strong><br \/>Prise en charge de la fonction de configuration PoE par port.<br \/><br \/><strong>Planification PoE<\/strong><br \/>Prend en charge la planification PoE par port pour activer\/d\u00e9sactiver les p\u00e9riph\u00e9riques PoE (PD).<br \/><br \/><strong>V\u00e9rification automatique<\/strong><br \/>V\u00e9rification de l'\u00e9tat de connexion des PD. Red\u00e9marrez les PD s'il n'y a pas de r\u00e9ponse.<br \/><br \/><strong>Retard de performances<\/strong><br \/>Les ports PoE peuvent \u00eatre activ\u00e9s avec une temporisation pour prot\u00e9ger le commutateur contre les surcharges.<br \/><strong><br \/>PoE non-stop, red\u00e9marrage en douceur<\/strong><br \/>Le commutateur alimente \u00e9galement les PD pendant le red\u00e9marrage en douceur."],"_porteinstellungen":["field_porteinstellungen_51cd7f"],"porteinstellungen":["Port d\u00e9sactiv\u00e9\/activ\u00e9, n\u00e9gociation automatique 10\/100\/100\/1000 Mbps et 10Gbps, contr\u00f4le de flux d\u00e9sactiv\u00e9\/activ\u00e9, contr\u00f4le du d\u00e9bit de donn\u00e9es sur chaque port, taille de trame max., contr\u00f4le de l'alimentation"],"_port_statusanzeige":["field_port_statusanzeige_459bcb"],"port_statusanzeige":["Affichage par port\u00a0: vitesse, \u00e9tat de la liaison, \u00e9tat du contr\u00f4le de flux, \u00e9tat de l'auton\u00e9gociation, \u00e9tat du tronc<br \/>Commutable sur l'affichage de l'\u00e9tat PoE"],"_layer3_funktionen":["field_layer3_funktionen_3e1228"],"layer3_funktionen":["IPv4 et IPv6\u00a0: routage statique et dynamique<br \/>OSPFv2\/v3 \/ RIPv1\/v2"],"_kommunikationsredundanz":["field_kommunikationsredundanz_5a8045"],"kommunikationsredundanz":["Standard Spanning Tree (STP), IEEE802.1d<br \/>Rapid Spanning Tree (RSTP), IEEE802.w<br \/>Multiple Spanning Tree (MSTP), IEEE802.1s<br \/>Ethernet Linear Protection Switching (ELPS), ITU-T G.8031<br \/>Ethernet Ring Protection Switching, (ERPS), ITU-T G.8032"],"_vlan":["field_vlan_86c905"],"vlan":["<strong>VLAN bas\u00e9 sur des balises selon 802.1Q<\/strong><br \/>Prend en charge jusqu'\u00e0 4K VLAN simultan\u00e9ment (sur 4096 ID VLAN)<br \/><br \/><strong>VLAN bas\u00e9 sur les ports<\/strong><br \/>Un membre de port d'un VLAN peut \u00eatre isol\u00e9 d'autres ports isol\u00e9s du m\u00eame VLAN et de VLAN priv\u00e9s.<br \/><br \/><strong>P\u00e9riph\u00e9rie de VLAN priv\u00e9 (PVE)<\/strong><br \/>Les VLAN priv\u00e9s sont bas\u00e9s sur le masque de port source et il n'y a aucune connexion aux VLAN. Cela signifie que les ID de VLAN et les ID de VLAN priv\u00e9s peuvent \u00eatre identiques.<br \/><br \/><strong>VLAN voix<\/strong><br \/>La fonction Voice VLAN permet de transf\u00e9rer le trafic vocal sur le Voice VLAN.<br \/><br \/><strong>VLAN invit\u00e9<\/strong><br \/>Avec la fonction VLAN invit\u00e9 IEEE 802.1X, un VLAN invit\u00e9 peut \u00eatre configur\u00e9 pour chaque port 802.1X sur l'appareil afin de fournir des services limit\u00e9s aux clients non conformes \u00e0 la norme 802.1X.<br \/><br \/><strong>VLAN Q-in-Q (double balise)<\/strong><br \/>Cela vous permet de d\u00e9finir des exigences sp\u00e9cifiques pour les ID de VLAN et le nombre de VLAN \u00e0 prendre en charge.<br \/><br \/><strong>VLAN protocole 802.1v<\/strong><br \/>La classification de plusieurs protocoles dans un seul VLAN impose souvent des limites de VLAN qui sont inappropri\u00e9es pour certains des protocoles. Cela n\u00e9cessite l'existence d'une entit\u00e9 non standard qui transmet les trames entre les VLAN en utilisant les protocoles pour lesquels les limites des VLAN sont inappropri\u00e9es.<br \/><br \/><strong>VLAN bas\u00e9 sur MAC<\/strong><br \/>La fonction VLAN bas\u00e9e sur MAC permet d'attribuer des paquets non marqu\u00e9s entrants \u00e0 un VLAN, ce qui permet de classer le trafic en fonction de l'adresse MAC source du paquet.<br \/><br \/><strong>VLAN bas\u00e9 sur un sous-r\u00e9seau IP<\/strong><br \/>Dans un VLAN bas\u00e9 sur un sous-r\u00e9seau IP, tous les postes de travail finaux d'un sous-r\u00e9seau IP sont affect\u00e9s au m\u00eame VLAN. Ce VLAN permet aux utilisateurs de d\u00e9placer leurs postes de travail sans avoir \u00e0 reconfigurer leurs adresses r\u00e9seau.<br \/><br \/><strong>S-VLAN<\/strong><br \/>S-VLAN bas\u00e9 sur QinQ.<br \/><br \/><strong>VLAN de gestion<\/strong><br \/>Le VLAN de gestion est utilis\u00e9 pour g\u00e9rer le commutateur \u00e0 distance \u00e0 l'aide de protocoles tels que Telnet, SSH, SNMP, Syslog, etc."],"_link_aggregation":["field_link_aggregation_66bf92"],"link_aggregation":["IEEE 802.3ad LACP \/ Static Trunk, prend en charge cinq groupes de troncs \u00e0 16 ports ou tronc statique."],"_qos":["field_qos_b0e298"],"qos":["<strong>File d'attente mat\u00e9rielle<\/strong><br \/>Prend en charge huit files d'attente mat\u00e9rielles.<br \/><br \/><strong>Classification<\/strong><br \/>Bas\u00e9 sur le port\u00a0: qualit\u00e9 de service du trafic par port<br \/>802.1p : La classe de service CoS QoS de couche 2 bas\u00e9e sur la priorit\u00e9 VLAN est un param\u00e8tre utilis\u00e9 dans les protocoles de donn\u00e9es et de voix pour distinguer les types de charges utiles contenues dans le paquet transmis.<br \/>Services diff\u00e9renci\u00e9s bas\u00e9s sur DSCP (DiffServ) DSCP-QoS de couche 3\u00a0: les paquets IP peuvent transporter soit une valeur de priorit\u00e9 IP (IPP), soit une valeur DSCP (Differentiated Services Code Point). QoS prend en charge l'utilisation des deux valeurs puisque les valeurs DSCP sont r\u00e9trocompatibles avec les valeurs de priorit\u00e9 IP.<br \/>Classification et re-marquage des ACL TCP\/IP : QoS par ACL<br \/><br \/><strong>Limitation de d\u00e9bit<\/strong><br \/>agent de police d'entr\u00e9e<br \/>Mise en forme de sortie et contr\u00f4le du d\u00e9bit par port<br \/><br \/><strong>Planification<\/strong><br \/>Priorit\u00e9 stricte et Round Robin pond\u00e9r\u00e9 (WRR) : Weighted Round Robin est un algorithme de planification qui utilise les pond\u00e9rations attribu\u00e9es aux files d'attente pour d\u00e9terminer la quantit\u00e9 de donn\u00e9es \u00e0 vider d'une file d'attente avant de passer \u00e0 la file d'attente suivante."],"_security":["field_security_1aa9ff"],"security":["<p><strong>Authentification certifi\u00e9e<\/strong><br \/>Une cl\u00e9 HTTPS priv\u00e9e peut \u00eatre stock\u00e9e pour l'acc\u00e8s de gestion.<br \/><br \/><strong>Gestion des utilisateurs<\/strong><br \/>Les droits d'utilisateur peuvent \u00eatre d\u00e9finis librement jusqu'\u00e0 15 niveaux.<br \/><br \/><strong>ACL<\/strong><br \/>Le commutateur permet jusqu'\u00e0 512 entr\u00e9es. Limite d'abandon ou de d\u00e9bit bas\u00e9e sur l'adresse MAC\/IP source\/destination ou l'ID VLAN. Les r\u00e8gles et conditions pour les paquets entrants peuvent \u00eatre d\u00e9finies par port. Les r\u00e8gles incluent les protocoles, les ports IP et les plages d'adresses. Les r\u00e8gles peuvent \u00eatre fix\u00e9es soit selon la proc\u00e9dure d'autorisation, soit selon la proc\u00e9dure d'exclusion. Les crit\u00e8res sont : Ports source et destination TCP\/UDP, priorit\u00e9 802.1p, type Ethernet, paquet ICMP (Internet Control Message Protocol).<br \/><br \/><strong>S\u00e9curit\u00e9 portuaire<br \/><\/strong>Gestion de l'adresse MAC par port et protection de source IP : L'adresse MAC peut \u00eatre v\u00e9rifi\u00e9e en combinaison avec l'adresse IP.<br \/><strong><br \/>Contr\u00f4le des temp\u00eates<br \/><\/strong>Emp\u00eache le trafic sur un r\u00e9seau local d'\u00eatre interrompu par une inondation de diffusion, de multidiffusion ou de monodiffusion sur un port.<strong><br \/><br \/>Authentification RADIUS, 802.1X<br \/><\/strong>Autorisation et comptabilit\u00e9, hachage MD5, VLAN invit\u00e9, mode h\u00f4te unique\/multiple et sessions uniques\/multiples<br \/>Prend en charge 802.1X bas\u00e9 sur IGMP RADIUS<br \/>Affectation VLAN dynamique<strong><br \/><br \/>Authentification TACACS+<br \/><\/strong>Le commutateur prend en charge l'authentification TACACS+. passer en tant que client.<strong><br \/><br \/>Coquille s\u00e9curis\u00e9e (SSH)<br \/><\/strong>SSH s\u00e9curise le trafic Telnet entrant ou sortant du commutateur, SSH v1 et v2 sont pris en charge<br \/><strong><br \/>Couche de sockets s\u00e9curis\u00e9e (SSL)<br \/><\/strong>SSL crypte le trafic HTTP, permettant un acc\u00e8s s\u00e9curis\u00e9 am\u00e9lior\u00e9 \u00e0 l'interface graphique de gestion bas\u00e9e sur un navigateur dans le commutateur.<strong><br \/><br \/>HTTPS & SSL (Web s\u00e9curis\u00e9)<br \/><\/strong>Hyper Text Transfer Protocol Secure (HTTPS) est la version s\u00e9curis\u00e9e de HTTP.<strong><br \/><br \/>Garde BPDU<br \/><\/strong>Le BPDU Guardian, une extension de STP, supprime un n\u0153ud qui renvoie les BPDU dans le r\u00e9seau. Il applique les limites du domaine STP et maintient la topologie active pr\u00e9visible en n'autorisant aucun p\u00e9riph\u00e9rique r\u00e9seau derri\u00e8re un port activ\u00e9 par BPDU Guard \u00e0 participer \u00e0 STP.<strong><br \/><br \/>Surveillance DHCP<br \/><\/strong>Avec la surveillance DHCP, le commutateur dispose d'une fonctionnalit\u00e9 qui agit comme un pare-feu entre les h\u00f4tes non approuv\u00e9s et les serveurs DHCP approuv\u00e9s.<strong><br \/><br \/>Protection de boucle<br \/><\/strong>La protection contre les boucles emp\u00eache les boucles monodiffusion, diffusion et multidiffusion inconnues dans les configurations de commutation de couche 2.<\/p>"],"_multicast":["field_multicast_ba1e09"],"multicast":["<strong>Surveillance IGMP v1\/v2\/v3<\/strong><br \/>IGMP limite le trafic multicast gourmand en bande passante aux candidats. Prend en charge 1024 groupes de multidiffusion.<br \/><br \/><strong>Interrogateur IGMP<\/strong><br \/>IGMP Querier est utilis\u00e9 par les commutateurs de surveillance pour prendre en charge un domaine de multidiffusion de couche 2 lorsqu'aucun routeur de multidiffusion n'est pr\u00e9sent.<br \/><br \/><strong>Proxy IGMP<\/strong><br \/>La surveillance IGMP avec rapport proxy ou suppression de rapport filtre activement les paquets IGMP pour r\u00e9duire la charge sur le routeur multidiffusion.<br \/><br \/><strong>Espionnage MLD v1\/v2<\/strong><br \/>Fournit les paquets de multidiffusion IPv6 uniquement aux destinataires requis.<br \/><br \/><strong>Enregistrement VLAN multidiffusion (MVR)<\/strong><br \/>Un VLAN d\u00e9di\u00e9 et configur\u00e9 manuellement, appel\u00e9 VLAN de multidiffusion, pour transf\u00e9rer le trafic de multidiffusion sur un r\u00e9seau de couche 2 en conjonction avec la surveillance IGMP."],"_topologie":["field_topologie_9884d8"],"topologie":[""],"_normen":["field_normen_529725"],"normen":["IEEE 802.3 10Base-T<br>IEEE 802.3u 100Base-TX\/100BASE-FX<br>IEEE 802.3z Gigabit SX\/LX<br>IEEE 802.3ab Gigabit 1000T<br>IEEE 802.3x Flow Control and Back pressure<br>IEEE 802.3ad Port trunk with LACP<br>IEEE 802.1d Spanning tree protocol<br>IEEE 802.1w Rapid spanning tree protocol<br>IEEE 802.1s Multiple spanning tree protocol<br>IEEE 802.1p Class ofservice<br>IEEE 802.1Q VLAN Tagging<br>IEEE 802.1x Port Authentication Network Control<br>IEEE 802.1ab LLDP<br>IEEE 802.3af\/at\/bt Power over Ethernet<br>IEEE 802.az Energy Efficient Ethernet<br>IEEE 1588v2 PTP Precisison Time Protocol"],"_dienste":["field_dienste_a25191"],"dienste":[""],"_fasertyp_leitertyp":["field_fasertyp_leitertyp_e31fa7"],"fasertyp_leitertyp":[""],"_faserzahl":["field_faserzahl_a0da28"],"faserzahl":[""],"_datenrate":["field_datenrate_8da3b7"],"datenrate":[""],"_bertragungsdistanz_max":["field_bertragungsdistanz_max_bffac8"],"bertragungsdistanz_max":[""],"_stecker":["field_stecker_1854cd"],"stecker":[""],"_zentrumswellenl_nge_rx":["field_zentrumswellenl_nge_rx_b119d7"],"zentrumswellenl_nge_rx":[""],"_zentrumswellenl_nge_tx":["field_zentrumswellenl_nge_tx_f29652"],"zentrumswellenl_nge_tx":[""],"_min_optische_sendeleistung":["field_min_optische_sendeleistung_a3573d"],"min_optische_sendeleistung":[""],"_max_optische_sendeleistung":["field_max_optische_sendeleistung_42d4f5"],"max_optische_sendeleistung":[""],"_opt_empfindlichkeit":["field_opt_empfindlichkeit_2ebd10"],"opt_empfindlichkeit":[""],"_max_optische_eingangsleistung":["field_max_optische_eingangsleistung_827f34"],"max_optische_eingangsleistung":[""],"_optisches_budget":["field_optisches_budget_863bc2"],"optisches_budget":[""],"_streckend_mpfung_min":["field_streckend_mpfung_min_163b75"],"streckend_mpfung_min":[""],"_bilddatei":["field_bilddatei_a89a9b"],"bilddatei":["RY-LPITE-442XGBME.png"],"_galerie_bilddateien":["field_galerie_bilddateien_366e92"],"galerie_bilddateien":[""],"_manual_datei":["field_manual_datei_31b30a"],"manual_datei":[""],"_ce_coc_datei":["field_ce_coc_datei_c8ed19"],"ce_coc_datei":["RY-LPITE-442XGME, CE Konformit\u00e4tserkl\u00e4rung.pdf|UL-CoC, RY-01.pdf|RY-LPITE-442XGME_FCC.pdf"],"_cad_datei":["field_cad_datei_b94fd2"],"cad_datei":["RY-LPITE-442XGBME.DXF"],"_visio_datei":["field_visio_datei_36ddbb"],"visio_datei":["2026-05-18, Shapes RY-Switches & LT-LPITE-402.zip"],"_lv_text_datei":["field_lv_text_datei_534b2d"],"lv_text_datei":[""],"_schema_dateien":["field_schema_dateien_0ac20d"],"schema_dateien":[""],"_fw_aktuell_dateien":["field_fw_aktuell_dateien_e30f8d"],"fw_aktuell_dateien":[""],"_fw_archiv_dateien":["field_fw_archiv_dateien_a93a95"],"fw_archiv_dateien":[""],"_fw_cve_datei":["field_fw_cve_datei_001b18"],"fw_cve_datei":[""],"_fw_release_notes":["field_fw_release_notes_5093d9"],"fw_release_notes":[""],"_fw_release_archiv":["field_fw_release_archiv_a7e5f8"],"fw_release_archiv":[""],"_foss_dokumentation":["field_foss_dokumentation_7067d5"],"foss_dokumentation":[""],"_weitere_downloads":["field_weitere_downloads_95d8f2"],"weitere_downloads":[""],"_filter_sfp_faserart":["field_filter_sfp_faserart_fe138d"],"filter_sfp_faserart":[""],"_filter_sfp_faserzahl":["field_filter_sfp_faserzahl_fdf79a"],"filter_sfp_faserzahl":[""],"_filter_sfp_datenrate":["field_filter_sfp_datenrate_368f6c"],"filter_sfp_datenrate":["10GBit\/s"],"_spalte1":["field_spalte1_dde496"],"spalte1":[""],"_f_montage_keine_angabe":["field_f_montage_keine_angabe_93fac5"],"f_montage_keine_angabe":[""],"_f_montage_19":["field_f_montage_19_c26a64"],"f_montage_19":[""],"_f_montage_hutschienenmontage":["field_f_montage_hutschienenmontage_d678b8"],"f_montage_hutschienenmontage":["x"],"_f_montage_tisch_oder_wandmontage":["field_f_montage_tisch_oder_wandmontage_9b0fcb"],"f_montage_tisch_oder_wandmontage":[""],"_f_poe_kein_poe":["field_f_poe_kein_poe_7918a4"],"f_poe_kein_poe":[""],"_f_poe_poe_af_15w":["field_f_poe_poe_af_15w_cb33f2"],"f_poe_poe_af_15w":["x"],"_f_poe_poe_at_30w":["field_f_poe_poe_at_30w_92a683"],"f_poe_poe_at_30w":["x"],"_f_poe_poe_60w":["field_f_poe_poe_60w_04e123"],"f_poe_poe_60w":["x"],"_f_poe_poe_bt_90w":["field_f_poe_poe_bt_90w_ebce8e"],"f_poe_poe_bt_90w":["x"],"_f_manage_management":["field_f_manage_management_9c657f"],"f_manage_management":["x"],"_f_manage_kein_management":["field_f_manage_kein_management_e82a78"],"f_manage_kein_management":[""],"_f_extend_utp":["field_f_extend_utp_f63adb"],"f_extend_utp":[""],"_f_extend_coax":["field_f_extend_coax_d1d3a0"],"f_extend_coax":[""],"_f_extend_fiber":["field_f_extend_fiber_98ddab"],"f_extend_fiber":[""],"_f_speisung_5vdc":["field_f_speisung_5vdc_b1d143"],"f_speisung_5vdc":[""],"_f_speisung_12vdc":["field_f_speisung_12vdc_6ad584"],"f_speisung_12vdc":[""],"_f_speisung_24vdc":["field_f_speisung_24vdc_56580d"],"f_speisung_24vdc":[""],"_f_speisung_48vdc":["field_f_speisung_48vdc_c7e215"],"f_speisung_48vdc":["x"],"_f_speisung_110_230vac":["field_f_speisung_110_230vac_444942"],"f_speisung_110_230vac":[""],"_f_speisung_poe":["field_f_speisung_poe_17061d"],"f_speisung_poe":[""],"_f_speisung_redundant":["field_f_speisung_redundant_99fa06"],"f_speisung_redundant":["x"],"_sw_tools":["field_sw_tools_9394d8"],"sw_tools":[""],"_pdf_link":["field_68e5002582269"],"pdf_link":["https:\/\/products.barox.ch\/?pdf=ry-lpite-442xgme"],"_wp_page_template":["default"],"_thumbnail_id":["7004"],"_product_image_gallery":[""],"_wpml_word_count":["508"],"_uag_css_file_name":["uag-css-7298.css"],"_uag_page_assets":["a:9:{s:3:\"css\";s:10265:\".wp-block-uagb-image{display:flex}.wp-block-uagb-image__figure{position:relative;display:flex;flex-direction:column;max-width:100%;height:auto;margin:0}.wp-block-uagb-image__figure img{height:auto;display:flex;max-width:100%;transition:box-shadow .2s ease}.wp-block-uagb-image__figure>a{display:inline-block}.wp-block-uagb-image__figure figcaption{text-align:center;margin-top:.5em;margin-bottom:1em}.wp-block-uagb-image .components-placeholder.block-editor-media-placeholder .components-placeholder__instructions{align-self:center}.wp-block-uagb-image--align-left{text-align:left}.wp-block-uagb-image--align-right{text-align:right}.wp-block-uagb-image--align-center{text-align:center}.wp-block-uagb-image--align-full .wp-block-uagb-image__figure{margin-left:calc(50% - 50vw);margin-right:calc(50% - 50vw);max-width:100vw;width:100vw;height:auto}.wp-block-uagb-image--align-full .wp-block-uagb-image__figure img{height:auto;width:100% !important}.wp-block-uagb-image--align-wide .wp-block-uagb-image__figure img{height:auto;width:100%}.wp-block-uagb-image--layout-overlay__color-wrapper{position:absolute;left:0;top:0;right:0;bottom:0;opacity:.2;background:rgba(0,0,0,.5);transition:opacity .35s ease-in-out}.wp-block-uagb-image--layout-overlay-link{position:absolute;left:0;right:0;bottom:0;top:0}.wp-block-uagb-image--layout-overlay .wp-block-uagb-image__figure:hover .wp-block-uagb-image--layout-overlay__color-wrapper{opacity:1}.wp-block-uagb-image--layout-overlay__inner{position:absolute;left:15px;right:15px;bottom:15px;top:15px;display:flex;align-items:center;justify-content:center;flex-direction:column;border-color:#fff;transition:.35s ease-in-out}.wp-block-uagb-image--layout-overlay__inner.top-left,.wp-block-uagb-image--layout-overlay__inner.top-center,.wp-block-uagb-image--layout-overlay__inner.top-right{justify-content:flex-start}.wp-block-uagb-image--layout-overlay__inner.bottom-left,.wp-block-uagb-image--layout-overlay__inner.bottom-center,.wp-block-uagb-image--layout-overlay__inner.bottom-right{justify-content:flex-end}.wp-block-uagb-image--layout-overlay__inner.top-left,.wp-block-uagb-image--layout-overlay__inner.center-left,.wp-block-uagb-image--layout-overlay__inner.bottom-left{align-items:flex-start}.wp-block-uagb-image--layout-overlay__inner.top-right,.wp-block-uagb-image--layout-overlay__inner.center-right,.wp-block-uagb-image--layout-overlay__inner.bottom-right{align-items:flex-end}.wp-block-uagb-image--layout-overlay__inner .uagb-image-heading{color:#fff;transition:transform .35s,opacity .35s ease-in-out;transform:translate3d(0, 24px, 0);margin:0;line-height:1em}.wp-block-uagb-image--layout-overlay__inner .uagb-image-separator{width:30%;border-top-width:2px;border-top-color:#fff;border-top-style:solid;margin-bottom:10px;opacity:0;transition:transform .4s,opacity .4s ease-in-out;transform:translate3d(0, 30px, 0)}.wp-block-uagb-image--layout-overlay__inner .uagb-image-caption{opacity:0;overflow:visible;color:#fff;transition:transform .45s,opacity .45s ease-in-out;transform:translate3d(0, 35px, 0)}.wp-block-uagb-image--layout-overlay__inner:hover .uagb-image-heading,.wp-block-uagb-image--layout-overlay__inner:hover .uagb-image-separator,.wp-block-uagb-image--layout-overlay__inner:hover .uagb-image-caption{opacity:1;transform:translate3d(0, 0, 0)}.wp-block-uagb-image--effect-zoomin .wp-block-uagb-image__figure img,.wp-block-uagb-image--effect-zoomin .wp-block-uagb-image__figure .wp-block-uagb-image--layout-overlay__color-wrapper{transform:scale(1);transition:transform .35s ease-in-out}.wp-block-uagb-image--effect-zoomin .wp-block-uagb-image__figure:hover img,.wp-block-uagb-image--effect-zoomin .wp-block-uagb-image__figure:hover .wp-block-uagb-image--layout-overlay__color-wrapper{transform:scale(1.05)}.wp-block-uagb-image--effect-slide .wp-block-uagb-image__figure img,.wp-block-uagb-image--effect-slide .wp-block-uagb-image__figure .wp-block-uagb-image--layout-overlay__color-wrapper{width:calc(100% + 40px) !important;max-width:none !important;transform:translate3d(-40px, 0, 0);transition:transform .35s ease-in-out}.wp-block-uagb-image--effect-slide .wp-block-uagb-image__figure:hover img,.wp-block-uagb-image--effect-slide .wp-block-uagb-image__figure:hover .wp-block-uagb-image--layout-overlay__color-wrapper{transform:translate3d(0, 0, 0)}.wp-block-uagb-image--effect-grayscale img{filter:grayscale(0%);transition:.35s ease-in-out}.wp-block-uagb-image--effect-grayscale:hover img{filter:grayscale(100%)}.wp-block-uagb-image--effect-blur img{filter:blur(0);transition:.35s ease-in-out}.wp-block-uagb-image--effect-blur:hover img{filter:blur(3px)}.uagb-block-e6f939b3.wp-block-uagb-image--layout-default figure img{box-shadow: 0px 0px 0 #00000070;}.uagb-block-e6f939b3.wp-block-uagb-image .wp-block-uagb-image__figure figcaption{font-style: normal;align-self: center;}.uagb-block-e6f939b3.wp-block-uagb-image--layout-overlay figure img{box-shadow: 0px 0px 0 #00000070;}.uagb-block-e6f939b3.wp-block-uagb-image--layout-overlay .wp-block-uagb-image--layout-overlay__color-wrapper{opacity: 0.2;}.uagb-block-e6f939b3.wp-block-uagb-image--layout-overlay .wp-block-uagb-image--layout-overlay__inner{left: 15px;right: 15px;top: 15px;bottom: 15px;}.uagb-block-e6f939b3.wp-block-uagb-image--layout-overlay .wp-block-uagb-image--layout-overlay__inner .uagb-image-heading{font-style: normal;color: #fff;opacity: 1;}.uagb-block-e6f939b3.wp-block-uagb-image--layout-overlay .wp-block-uagb-image--layout-overlay__inner .uagb-image-heading a{color: #fff;}.uagb-block-e6f939b3.wp-block-uagb-image--layout-overlay .wp-block-uagb-image--layout-overlay__inner .uagb-image-caption{opacity: 0;}.uagb-block-e6f939b3.wp-block-uagb-image--layout-overlay .wp-block-uagb-image__figure:hover .wp-block-uagb-image--layout-overlay__color-wrapper{opacity: 1;}.uagb-block-e6f939b3.wp-block-uagb-image .wp-block-uagb-image--layout-overlay__inner .uagb-image-separator{width: 30%;border-top-width: 2px;border-top-color: #fff;opacity: 0;}.uagb-block-e6f939b3.wp-block-uagb-image .wp-block-uagb-image__figure img{width: px;height: auto;}.uagb-block-e6f939b3.wp-block-uagb-image .wp-block-uagb-image__figure:hover .wp-block-uagb-image--layout-overlay__inner .uagb-image-caption{opacity: 1;}.uagb-block-e6f939b3.wp-block-uagb-image .wp-block-uagb-image__figure:hover .wp-block-uagb-image--layout-overlay__inner .uagb-image-separator{opacity: 1;}.uagb-block-e6f939b3.wp-block-uagb-image--layout-default figure:hover img{box-shadow: 0px 0px 0 #00000070;}.uagb-block-e6f939b3.wp-block-uagb-image--layout-overlay figure:hover img{box-shadow: 0px 0px 0 #00000070;}@media only screen and (max-width: 976px) {.uagb-block-e6f939b3.wp-block-uagb-image .wp-block-uagb-image__figure img{width: px;height: auto;}}@media only screen and (max-width: 767px) {.uagb-block-e6f939b3.wp-block-uagb-image .wp-block-uagb-image__figure img{width: px;height: auto;}.uagb-block-e6f939b3.wp-block-uagb-image{text-align: center;justify-content: center;align-self: center;}.uagb-block-e6f939b3 .wp-block-uagb-image__figure{align-items: center;}}.wp-block-uagb-advanced-heading h1,.wp-block-uagb-advanced-heading h2,.wp-block-uagb-advanced-heading h3,.wp-block-uagb-advanced-heading h4,.wp-block-uagb-advanced-heading h5,.wp-block-uagb-advanced-heading h6,.wp-block-uagb-advanced-heading p,.wp-block-uagb-advanced-heading div{word-break:break-word}.wp-block-uagb-advanced-heading .uagb-heading-text{margin:0}.wp-block-uagb-advanced-heading .uagb-desc-text{margin:0}.wp-block-uagb-advanced-heading .uagb-separator{font-size:0;border-top-style:solid;display:inline-block;margin:0 0 10px 0}.wp-block-uagb-advanced-heading .uagb-highlight{color:#f78a0c;border:0;transition:all .3s ease}.uag-highlight-toolbar{border-left:0;border-top:0;border-bottom:0;border-radius:0;border-right-color:#1e1e1e}.uag-highlight-toolbar .components-button{border-radius:0;outline:none}.uag-highlight-toolbar .components-button.is-primary{color:#fff}.wp-block-uagb-advanced-heading.uagb-block-64c3d165.wp-block-uagb-advanced-heading {margin-bottom: -20px;}.wp-block-uagb-advanced-heading.uagb-block-64c3d165.wp-block-uagb-advanced-heading .uagb-desc-text{margin-bottom: 15px;}.wp-block-uagb-advanced-heading.uagb-block-64c3d165.wp-block-uagb-advanced-heading .uagb-highlight{font-style: normal;font-weight: Default;background: #007cba;color: #fff;-webkit-text-fill-color: #fff;}.wp-block-uagb-advanced-heading.uagb-block-64c3d165.wp-block-uagb-advanced-heading .uagb-highlight::-moz-selection{color: #fff;background: #007cba;-webkit-text-fill-color: #fff;}.wp-block-uagb-advanced-heading.uagb-block-64c3d165.wp-block-uagb-advanced-heading .uagb-highlight::selection{color: #fff;background: #007cba;-webkit-text-fill-color: #fff;}.wp-block-uagb-advanced-heading.uagb-block-ef07010e.wp-block-uagb-advanced-heading {margin-bottom: -20px;}.wp-block-uagb-advanced-heading.uagb-block-ef07010e.wp-block-uagb-advanced-heading .uagb-desc-text{margin-bottom: 15px;}.wp-block-uagb-advanced-heading.uagb-block-ef07010e.wp-block-uagb-advanced-heading .uagb-highlight{font-style: normal;font-weight: Default;background: #007cba;color: #fff;-webkit-text-fill-color: #fff;}.wp-block-uagb-advanced-heading.uagb-block-ef07010e.wp-block-uagb-advanced-heading .uagb-highlight::-moz-selection{color: #fff;background: #007cba;-webkit-text-fill-color: #fff;}.wp-block-uagb-advanced-heading.uagb-block-ef07010e.wp-block-uagb-advanced-heading .uagb-highlight::selection{color: #fff;background: #007cba;-webkit-text-fill-color: #fff;}.wp-block-uagb-advanced-heading.uagb-block-63d4c36f.wp-block-uagb-advanced-heading {margin-bottom: -20px;}.wp-block-uagb-advanced-heading.uagb-block-63d4c36f.wp-block-uagb-advanced-heading .uagb-desc-text{margin-bottom: 15px;}.wp-block-uagb-advanced-heading.uagb-block-63d4c36f.wp-block-uagb-advanced-heading .uagb-highlight{font-style: normal;font-weight: Default;background: #007cba;color: #fff;-webkit-text-fill-color: #fff;}.wp-block-uagb-advanced-heading.uagb-block-63d4c36f.wp-block-uagb-advanced-heading .uagb-highlight::-moz-selection{color: #fff;background: #007cba;-webkit-text-fill-color: #fff;}.wp-block-uagb-advanced-heading.uagb-block-63d4c36f.wp-block-uagb-advanced-heading .uagb-highlight::selection{color: #fff;background: #007cba;-webkit-text-fill-color: #fff;}\";s:2:\"js\";s:0:\"\";s:18:\"current_block_list\";a:3:{i:0;s:11:\"core\/search\";i:1;s:10:\"uagb\/image\";i:2;s:21:\"uagb\/advanced-heading\";}s:8:\"uag_flag\";b:1;s:11:\"uag_version\";s:10:\"1782406820\";s:6:\"gfonts\";a:0:{}s:10:\"gfonts_url\";s:0:\"\";s:12:\"gfonts_files\";a:0:{}s:14:\"uag_faq_layout\";b:0;}"]},"uagb_featured_image_src":{"full":["https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME.png",211,409,false],"thumbnail":["https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME-150x150.png",150,150,true],"medium":["https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME-155x300.png",155,300,true],"medium_large":["https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME.png",211,409,false],"large":["https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME.png",211,409,false],"1536x1536":["https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME.png",211,409,false],"2048x2048":["https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME.png",211,409,false],"woocommerce_thumbnail":["https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME.png",211,409,false],"woocommerce_single":["https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME.png",211,409,false],"woocommerce_gallery_thumbnail":["https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME-100x100.png",100,100,true],"yith-woocompare-image":["https:\/\/products.barox.ch\/wp-content\/uploads\/2025\/11\/RY-LPITE-442XGBME.png",79,154,false]},"uagb_author_info":{"display_name":"","author_link":"https:\/\/products.barox.ch\/fr\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"Montage sur rail DIN|Ports cuivre : 8 x10|Ports Fibre : 2 x SFP\/SFP+ 1G\/10G|Avec management, fonctions L3|Non Stop PoE|OSPFv2\/v3 und RIPv1\/v2|IEEE 1588 V2, PTP|Sans ventilateur|Alimentation 48-57VDC, redondont","_links":{"self":[{"href":"https:\/\/products.barox.ch\/fr\/wp-json\/wp\/v2\/product\/7298","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/products.barox.ch\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/products.barox.ch\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/products.barox.ch\/fr\/wp-json\/wp\/v2\/media\/7004"}],"wp:attachment":[{"href":"https:\/\/products.barox.ch\/fr\/wp-json\/wp\/v2\/media?parent=7298"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/products.barox.ch\/fr\/wp-json\/wp\/v2\/product_brand?post=7298"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/products.barox.ch\/fr\/wp-json\/wp\/v2\/product_cat?post=7298"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/products.barox.ch\/fr\/wp-json\/wp\/v2\/product_tag?post=7298"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}